Champion Passive House: a certified Passive House Plus in Williamstown
A single storey family home in Williamstown, built to the Passive House Plus standard, which means it is not only extremely efficient, it also generates its own renewable energy from the roof.
Passive House Plus, and what the Plus actually means
Standard Passive House certification is about using as little energy as possible. Passive House Plus goes a step further, because the home also has to generate a set amount of renewable energy on site and meet a tighter limit on the total energy it draws. On Champion Passive House, that job falls to 20 solar panels on the roof, an 8.3 kW system the certified PHPP estimates will produce 9,543 kWh a year, or 53 kWh for every square metre of the home's footprint.
Every figure below comes from the certified PHPP (the Passive House Institute's energy modelling tool), checked by an independent certifier, with the airtightness result taken from an on site blower door test.
| Measure | Champion Passive House | Passive House Plus requirement |
|---|---|---|
| Airtightness (ACH50) | 0.39 | 0.6 or less |
| Heating demand (kWh/m² per year) | 13.8 | 15 or less |
| Cooling demand (kWh/m² per year) | 3.0 | 15 or less |
| Renewable primary energy (kWh/m² per year) | 36.4 | 45 or less |
| Solar generation (kWh per m² of footprint per year) | 53 | 52 or more for this home |
| Hours above 25°C | 5.4% | 10% or less |
| Hours with excess humidity | 0% | 10% or less |
The overheating figure sits just over the Passive House Institute's 5% recommendation and well inside the 10% limit, so on the hottest Williamstown afternoons the house stays comfortable without the air conditioning working overtime.
Almost 50 times tighter than the average Melbourne home
CSIRO testing puts the average Melbourne home at around 19 air changes per hour at 50 pascals, which is why so many houses here are a glorified tent in winter. Champion Passive House was tested by Drew Kroker of Passive Tech on 13 November 2023 and came in at 0.40 under depressurisation and 0.39 under pressurisation, for an average of 0.39, almost 50 times tighter.
That result comes down to a continuous airtight membrane wrapped around the whole house and a service cavity on the inside of the walls, so power points, lights and plumbing never have to punch a hole through it.
What sits behind the plasterboard
The house sits on a suspended timber floor over a ventilated crawl space, with R5 batts packed between 200 mm floor joists under a particleboard deck, giving the floor a U value of 0.258 W/m²K. Insulating a raised floor properly is harder than insulating a slab, and it is one of the details that quietly makes or breaks a single storey Passive House.
The walls are 140 mm timber studs filled with Polysorb R3.5 batts, with a 45 mm service cavity on the inside holding a further R0.8, for a U value of 0.294. Above, the ceiling carries R7.0 Bradford batts for a U value of 0.155.
Triple glazed timber windows
The windows and doors are LogikWin 68 timber frames with an aluminium outer face, fitted with PressGlass Silverstar triple glazing filled with argon. Across the whole house the windows average a U value of 0.98 W/m²K, which is the difference between glass that feels cold to stand next to in July and glass you do not notice at all.
The brief asked for generous glazing so the family could feel connected to the garden, and triple glazing is what lets you have that much glass without paying for it in heat loss.
Fresh, filtered air around the clock
A Zehnder ComfoAir 350 heat recovery ventilation system runs quietly in the background, replacing the whole volume of air in the house roughly every two and a half hours. Stale air is drawn out of the kitchen, bathrooms and laundry, filtered fresh air is supplied to the bedrooms and living areas, and the unit recovers 80.2% of the heat on the way through.
Heating and cooling is handled by a split system heat pump, and hot water comes from a heat pump with a 315 litre tank.
Built for a young family
The clients came to us wanting a home that was comfortable, healthy and cheap to run for a family with two kids, without giving up the light and connection to the outdoors they loved. It was our second certified Passive House, and the owners singled out the fortnightly on site meetings and a clean, organised site as highlights of the build.
As the owners put it, "The performance of our passive house is simply unparalleled."
How it stacks up against our other certified homes
Here is how Champion Passive House sits alongside our other certified new builds, with our Retrofit Rifle EnerPHit in Williamstown left out because it is certified to the separate retrofit standard.
| Project | Airtightness (ACH50) | Heating demand (kWh/m² per year) |
|---|---|---|
| Pigeon Passive House, Yarraville | 0.26 | 9.0 |
| Champion Passive House, Williamstown | 0.39 | 13.8 |
| Forrest Passive House, Spotswood | 0.41 | 13.1 |
| Wellington Passive House, Flemington | 0.47 | 13.4 |
| Parade Passive House, Ascot Vale | 0.49 | 14.8 |
Every one of them is under the 0.6 airtightness limit, every one was tested, and every number above comes from a certified PHPP rather than a brochure.
The team behind it
Design and energy modelling by Altereco Design, certification by Emilia Iacovino of Detail Green, and airtightness testing by Drew Kroker of Passive Tech, with Carland Constructions as the builder.
If you are planning a new build or a Passive House renovation in Melbourne, book a call and we will talk you through how we would approach yours.
Frequently asked questions
What is Champion Passive House?
Champion Passive House is a single storey family home in Williamstown, Melbourne, and the second certified Passive House built by Carland Constructions. It was designed by Altereco Design and certified to the Passive House Plus standard by Detail Green in December 2024.
What is the difference between Passive House and Passive House Plus?
Passive House Plus has the same comfort and efficiency requirements as standard Passive House, but the home must also generate renewable energy on site and meet a tighter limit on renewable primary energy. Champion Passive House generates 53 kWh per square metre of footprint each year from its rooftop solar.
How airtight is Champion Passive House?
It tested at 0.39 air changes per hour at 50 pascals in November 2023, against a Passive House limit of 0.6. The average Melbourne home tests at around 19, so this house is almost 50 times tighter.
How much energy does it need for heating?
The certified PHPP shows a heating demand of 13.8 kWh per square metre per year, under the Passive House limit of 15, across a treated floor area of 161.3 m².
Can you build a Passive House on a raised timber floor?
Yes. Champion Passive House sits on a suspended timber floor over a ventilated crawl space, insulated with R5 batts between 200 mm joists for a U value of 0.258 W/m²K, and the floor is sealed into the airtight layer along with the walls and ceiling.
Who designed, built and certified Champion Passive House?
Altereco Design designed the house and completed the energy modelling, Carland Constructions built it, Detail Green certified it, and Passive Tech carried out the airtightness testing.