Parade Passive House: a Victorian face with a SIPs Passive House behind it

From the street in Ascot Vale, it looks like it could have been there for a hundred years. Behind that Victorian style front sits the largest home we have certified, built almost entirely from panels made in a factory.

The owners were new to Passive House. They didn't come to us with a spec sheet or a list of acronyms, they came wanting a home that was comfortable, healthy and resilient, that cost very little to run and that was built properly. The heritage feel of the street meant the front had to sit quietly alongside its neighbours, so the challenge was to deliver one of the highest performance standards in the world without it looking like a science experiment.

Our answer was structural insulated panels, better known as SIPs, and it was the first time we had used them as the main way of building a home.

The short answer Parade Passive House is a two storey home in Ascot Vale, Melbourne, built by Carland Constructions with SIPs walls and roof behind a Victorian style facade. Designed by Gruen Eco Design and certified Passive House Plus by HIP V. HYPE in August 2025, it tested at 0.49 air changes per hour at 50 pascals and needs 14.8 kWh/m² of heating a year.
202.4m² treated floor area, our largest
0.49ACH50 airtightness, limit 0.6
14.8kWh/m² heating a year, limit 15
9,268kWh of solar generated a year

A house that arrives in pieces

A SIP is a sandwich. Two sheets of OSB (a strong engineered timber board) sit either side of a thick core of solid insulation, a bit like the lid of a good esky. The panels are the structure and the insulation in one, so instead of building a timber frame and stuffing it with batts, the walls and roof arrive on site as large, finished panels ready to stand up.

The catch is that the thinking all has to happen first. Every window and door opening is cut at the factory, so the window sizes, the reveal details and the Passive House energy model all had to be locked in before a single panel was made. On a normal build you can change your mind about a window late in the piece. With SIPs, that decision is made months earlier, and it rewards a team that plans properly.

Why a Victorian front is harder than it looks

A simple box is the easiest shape to make into a Passive House. A Victorian style front is the opposite, with more corners, more roof shapes and more places where one surface meets another, and every one of those meeting points is somewhere air can sneak through and heat can slip out.

So the street got the house it expected, and behind the scenes every one of those junctions had to be detailed, sealed and checked so the look never cost the house its performance.

The hard part is the joins

The panels themselves are very airtight. The weak points are where they meet: at the corners, where the walls meet the roof, around every window and where the walls meet the floor. Each of those junctions has to be sealed continuously, because a gap there doesn't just let a draught in, it can let warm, moist air into the insulation core where it has no business being.

When Drew Kroker ran the blower door test on 15 August 2023, the house came in at 0.47 air changes per hour under depressurisation and 0.51 under pressurisation, an average of 0.49. That is comfortably under the Passive House limit of 0.6, and it is almost 40 times tighter than the average Melbourne home at around 19. It is also the highest result across our certified homes, which on the largest house we have built, with 660 cubic metres of air and the most junctions to seal, is a result we are proud of.

The one part that isn't SIPs

The floor is a concrete slab rather than panels, sitting on 75 mm of XPS insulation with plywood and a timber finish on top. The ground under Melbourne stays at a fairly steady temperature all year, so the floor works less hard than the walls and roof, and the insulation underneath stops the slab acting like a cold plate in winter.

Fresh air in, power from the roof

A Zehnder ComfoAir Q350 heat recovery ventilation system supplies filtered fresh air around the clock and recovers 79.5% of the heat from the stale air on its way out. In summer, a bypass lets cooler night air in without warming it back up. Heating and cooling is handled by Mitsubishi split systems, hot water comes from a heat pump with a 400 litre tank, and the windows are Kömmerling C70 frames with argon filled double glazing, plus Velux skylights.

Up top, the solar panels are expected to generate 9,268 kWh a year, or 66 kWh for every square metre of the home's footprint, beating the 60 that Passive House Plus asks for. That is what moved the house from Passive House to Passive House Plus.

One honest number: the certified model has the house above 25°C for 7% of the year. That is over the Passive House Institute's 5% recommendation and inside its 10% limit, and it is something we keep a close eye on with every two storey home we build.

What the owners said

The owners told us the communication and collaboration were what stood out, that they were brought into the decisions and the fine detail, and that the team handled some major challenges along the way and is still there for them now they have moved in. As they put it, "He is a certified Passive House builder, which is what we were looking for."

The numbers

Every figure below comes from the certified PHPP (the Passive House Institute's energy modelling tool), checked by an independent certifier, with airtightness taken from the on site blower door test.

MeasureParade Passive HousePassive House Plus requirement
Airtightness (ACH50)0.490.6 or less
Heating demand (kWh/m² per year)14.815 or less
Cooling demand (kWh/m² per year)4.515 or less
Renewable primary energy (kWh/m² per year)40.145 or less
Solar generation (kWh per m² of footprint per year)6660 or more
Hours above 25°C7.0%10% or less
Hours with excess humidity0%10% or less
Treated floor area202.4 m²

What's in the walls, roof and floor

  • Walls: 165 mm SIPs (11 mm OSB, 143 mm insulated core, 11 mm OSB), a 35 mm battened service cavity and plasterboard, U value 0.221 W/m²K
  • Roof: SIPs with a 187 mm insulated core, U value 0.186 W/m²K
  • Floor: 130 mm concrete slab on 75 mm XPS, with plywood and a timber finish, U value 0.373 W/m²K
  • Windows: Kömmerling C70 frames with argon filled double glazing, plus Velux skylights
  • Ventilation: Zehnder ComfoAir Q350, 79.5% effective heat recovery with summer bypass
  • Heating, cooling and hot water: Mitsubishi split systems and a 400 litre heat pump hot water system

How it stacks up against our other certified homes

ProjectAirtightness (ACH50)Heating demand (kWh/m² per year)
Pigeon Passive House, Yarraville0.269.0
Champion Passive House, Williamstown0.3913.8
Forrest Passive House, Spotswood0.4113.1
Wellington Passive House, Flemington0.4713.4
Parade Passive House, Ascot Vale0.4914.8

Our Retrofit Rifle EnerPHit in Williamstown is left out of the table because it is certified to the separate retrofit standard.

The team behind it

Design by Gruen Eco Design, energy modelling by Prorate Energy Consulting, certification by Marcus Strang of HIP V. HYPE, and airtightness testing by Drew Kroker, with Carland Constructions as the builder.

Thinking about SIPs for your own build? The panels are only as good as the joins, so ask any builder how they plan to seal them before you ask what they cost.

If you are planning a new build or a Passive House renovation in Melbourne, book a call and we will talk you through whether SIPs or a timber frame suits your project.

Frequently asked questions

What is Parade Passive House?

Parade Passive House is a two storey home in Ascot Vale, Melbourne, built by Carland Constructions using SIPs walls and roof behind a Victorian style facade. It was designed by Gruen Eco Design and certified to the Passive House Plus standard by HIP V. HYPE in August 2025, and at 202.4 m² it is the largest home Carland Constructions has certified.

What are SIPs?

SIPs, or structural insulated panels, are made from two sheets of OSB with a solid insulation core between them. They act as the structure and the insulation at the same time, and they are made in a factory with the window and door openings already cut.

Can you build a Passive House with SIPs?

Yes. Parade Passive House used SIPs for its walls and roof and was certified Passive House Plus in 2025, with an airtightness result of 0.49 air changes per hour and a heating demand of 14.8 kWh per square metre per year.

Do SIPs change how a build is planned?

They do. Because the panels are cut in a factory, every window size, reveal detail and the Passive House energy model have to be finalised before manufacture. Decisions that would normally be made during construction are made months earlier, during design.

Are SIPs automatically airtight?

The panels themselves are very airtight, but the joins are not. Corners, wall to roof junctions, window openings and the connection to the floor all need to be sealed continuously, or moist air can reach the insulation core. Airtightness on a SIPs home comes down to how carefully those junctions are detailed and built.